{"id":2243,"date":"2019-09-25T08:44:18","date_gmt":"2019-09-25T06:44:18","guid":{"rendered":"https:\/\/www.haasetank.de\/?post_type=reference&#038;p=2243"},"modified":"2020-05-18T09:27:26","modified_gmt":"2020-05-18T07:27:26","slug":"flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster","status":"publish","type":"reference","link":"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/","title":{"rendered":"Flat bottom tank for a brine thermal bath in Bad Elster"},"content":{"rendered":"\n<p>The positive effects of mineral healing water on the human organism have been used for pain relief and healing for hundreds of years. The healing springs in Bad Elster have only been developed for a short time, which is the responsibility of the S\u00e4chsische Staatsb\u00e4der GmbH.<br>When building the new&nbsp;<a>brine thermal bath<\/a>, the focus from the very beginning was on the resistance of the tanks and pipes to the highly saline and aggressive brine solution. The search for a suitable material quickly led to glass fiber reinforced plastic (GRP). The Haase company installed a total of 4 flat-bottom tanks for different applications, with the usable volume varying between 1,600 liters and 35,200 liters.<\/p>\n\n\n\n<figure class=\"wp-block-gallery columns-4 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-1024x682.jpg\" alt=\"These Haase flat-bottom tanks were designed as collecting tanks, calming and overflow basins as well as cold water tanks.\" data-id=\"2244\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-scaled.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_01\/\" class=\"wp-image-2244\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-1024x682.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-300x200.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-768x512.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-1536x1023.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-2048x1364.jpg 2048w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_01-600x400.jpg 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">These Haase flat-bottom tanks were designed as collecting tanks, calming and overflow basins as well as cold water tanks.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-1024x682.jpg\" alt=\"This flat bottom tank is used as an overflow basin.\" data-id=\"2245\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-scaled.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_02\/\" class=\"wp-image-2245\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-1024x682.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-300x200.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-768x512.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-1536x1023.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-2048x1364.jpg 2048w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_02-600x400.jpg 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">This flat bottom tank is used as an overflow basin.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-1024x768.jpg\" alt=\"Two of the four falt-bottom tanks are equipped with heating and insulation.\" data-id=\"4262\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-scaled.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_04\/\" class=\"wp-image-4262\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-1024x768.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-300x225.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-768x576.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-1536x1152.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_04-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">Two of the four falt-bottom tanks are equipped with heating and insulation.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-768x1024.jpg\" alt=\"The flat-bottom tanks were assembled on site and connected to the system using a GRP flange.\" data-id=\"2247\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-scaled.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_03\/\" class=\"wp-image-2247\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-768x1024.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-225x300.jpg 225w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-1152x1536.jpg 1152w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-1536x2048.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/09\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_03-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">The flat-bottom tanks were assembled on site and connected to the system using a GRP flange.<\/figcaption><\/figure><\/li><\/ul><\/figure>\n\n\n\n<figure class=\"wp-block-gallery columns-4 is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling-1024x724.jpg\" alt=\"Technical drawing of a flat-bottom tank as a settling tank.\" data-id=\"3106\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_settling\/\" class=\"wp-image-3106\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling-1024x724.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling-300x212.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling-768x543.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling-1536x1085.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_settling.jpg 1755w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">Technical drawing of a flat-bottom tank as a settling tank.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water-1024x724.jpg\" alt=\"Technical drawing of a flat-bottom tank as a cold water tank\" data-id=\"3107\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_cold_water\/\" class=\"wp-image-3107\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water-1024x724.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water-300x212.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water-768x543.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water-1536x1085.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_cold_water.jpg 1755w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">Technical drawing of a flat-bottom tank as a cold water tank.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank-1024x724.jpg\" alt=\"Technical drawing of a flat-bottom tank as a collecting basin.\" data-id=\"3108\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_collecting_tank\/\" class=\"wp-image-3108\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank-1024x724.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank-300x212.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank-768x543.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank-1536x1085.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_collecting_tank.jpg 1755w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">Technical drawing of a flat-bottom tank as a collecting basin.<\/figcaption><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><a href=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow-1024x724.jpg\" alt=\"Technical drawing of flat-bottom tanks as an overflow basin\" data-id=\"3109\" data-full-url=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow.jpg\" data-link=\"https:\/\/www.haasetank.de\/en\/references\/flat-bottom-tank-for-a-brine-thermal-bath-in-bad-elster\/flat_bottom_tank_for_a_brine_thermal_bath_in_bad_elster_overflow\/\" class=\"wp-image-3109\" srcset=\"https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow-1024x724.jpg 1024w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow-300x212.jpg 300w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow-768x543.jpg 768w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow-1536x1085.jpg 1536w, https:\/\/www.haasetank.de\/app\/uploads\/sites\/2\/2019\/10\/Flat_bottom_tank_for_a_brine_thermal_bath_in_Bad_Elster_overflow.jpg 1755w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"blocks-gallery-item__caption\">Technical drawing of flat-bottom tanks as an overflow basin.<\/figcaption><\/figure><\/li><\/ul><\/figure>\n","protected":false},"author":5,"featured_media":2244,"template":"","meta":{"_acf_changed":false,"editor_notices":[],"footnotes":""},"reference_category":[13],"class_list":["post-2243","reference","type-reference","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/reference\/2243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/reference"}],"about":[{"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/types\/reference"}],"author":[{"embeddable":true,"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/users\/5"}],"version-history":[{"count":14,"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/reference\/2243\/revisions"}],"predecessor-version":[{"id":6198,"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/reference\/2243\/revisions\/6198"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/media\/2244"}],"wp:attachment":[{"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/media?parent=2243"}],"wp:term":[{"taxonomy":"reference_category","embeddable":true,"href":"https:\/\/www.haasetank.de\/en\/wp-json\/wp\/v2\/reference_category?post=2243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}